2-95
D1VA UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Direct Operated Directional Control Valve
Series D1VACharacteristics
Pneumatically controlled directional control valves of
series D1VA are based on the standard D1VW design.
The main spool is operated via an auxiliary spool of lager
diameter. Thus enables low operating pressures from 3
to 5 bar.
Pneumatic connection via thread G1/8 in the end caps.
General
Design Directional spool valve
Actuation Pneumatic
Series
D1VA
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A06, ISO 4401, NFPA D03, CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
MTTF
D
value [years] 150
Weight [kg] 1.3
Hydraulic
Max. operating pressure [bar] P, A B: 350; T: 105
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min] 60
1)
Leakage at 350 bar (per flow path) [ml/min] up to 60
1)
Operating pressure w/o tank pressure
with max tank
[bar]
[bar]
min. 3
min. 5
Static / Dynamic
Step response The response times depend on the pilot oil pressure and on the speed of the increase /
decrease of the pilot pressure.
Recommended values are (act./deact.)
depending on pilot pressure and pipe
length
[ms] 13/28
Technical data
1)
depending on spool
A B